◆ Digital signal complying IEC61850-9-1 / IEC61850-9-2 protocols.
◆ Synchronize with GPS,IRIG-B.
◆ Suitable testing for all kinds of electromagnetic relays,microcomputer relays.
Model | Current Outputs | Voltage Outputs | ||||
K3166i | 6×35A@450VA max / 3×70A@850VA max | 7×310V@90VA max | ||||
K3163i | 6×35A@450VA max / 3×70A@850VA max | 4×310V@124VA max | ||||
K3130i | 3×35A@450VA max | 4×310V@124VA max |
1. Two 100Mbit Optical Fiber ports for SMV and GOOSE simulations(exchangeable with RJ45).
2. 6×35A & 4×310V independent high burden output channels.
3. 13 channels independent low-level signal outputs.
4. AC/DC measurement(8 channels inputs,class 0.05,0-600V/0-5A,auto range).
5. Transducer calibartion (class 0.02).
6. Energy meter calibration(Mechanical & Electronic meters).
7. Transient play back up to 3KHZ.
8. Light weight <18kg.
9.Fully function KRT software testing modules.
10.3-Years guarantee of free repair and life-long maintenance.
11.Free software upgrade.
Testing Items | ANSI® No. | |||||
IEC61850 numerical IEDs relay & merge unit | -- | |||||
Distance protection relay | 21 | |||||
Synchronising or synchronism-check relays | 25 | |||||
Undervoltage relays | 27 | |||||
Directional Power relays | 32 | |||||
Undercurrent or underpower relays | 37 | |||||
Negative sequence overcurrent relays | 46 | |||||
Overcurrent/ground fault relays | 50 | |||||
Inverse time overcurrent/ground fault relays | 51 | |||||
Power factor relays | 55 | |||||
Overvoltage relays | 59 | |||||
Voltage or current balance relays | 60 | |||||
Directional overcurrent relays | 67 | |||||
Directional ground fault relays | 67N | |||||
DC overcurrent relays | 76 | |||||
Phase-angle measuring or out-of-step protection relays | 78 | |||||
Automatic reclosing devices | 79 | |||||
Frequency relays | 81 | |||||
Motor overload protection relays | 86 | |||||
Differential protection relays | 87 | |||||
Directional voltage relays | 91 | |||||
Voltage and power directional relays | 92 | |||||
Tripping relays | 94 | |||||
Voltage regulating relays | -- | |||||
Overimpedance relays, Z> | -- | |||||
Underimpedance relays, Z | -- | |||||
Time-delay relays | -- |
1. 10 Channels (6×35A & 4×310V) outputs, each output channels are independent and simultaneous
control of magnitude, phase angle and frequency values, able to inject DC, AC sine wave and up
to 20 × harmonics.
2. Variable battery simulator, DC 0-350V, 140Watts max.
3. 13 Low-level channels outputs up to 8Vac/10Vdc max.
4. 0-600V / 0-5A AC/DC measurement in 0.05 class.
5. Graphical test modules and templates for testing of various relays.
6. Quick relay testing facility in Manual mode.
7. Shot/Search/Check, Point & Click testing.
8. RIO/XRIO import & export facility.
9. Switch on to fault test(SOTF).
10.Power system model for dynamic testing.
11.Inbuilt GPS and IRIG-B sync end-to-end testing.
12.Online Vector display.
13.Automatic test results assume.
14.Automatic test report creation.
15.Anti-clipping detect,wrong wiring connect alarm and self-protect, overload and overheat protection.
Voltage Outputs | ||||||
Output Range & Power | 4×310V ac (L-N) | 124VA max each | ||||
2×620V ac (L-L) | 248VA max each | |||||
3×350V dc (L-N) | 140W max each | |||||
Accuracy | AC:<0.03%Rd + 0.02Rg Typ. / <0.07%Rd + 0.03Rg Guar. | |||||
DC: ±10mV @<5V,±0.5% @ ≥5V | ||||||
Resolution | 1mV | |||||
Distortion | <0.05% Typ. / <0.1% Guar. | |||||
Current Outputs | ||||||
Output Range & Power | 6×35A ac(L-N) | 450VA max single | ||||
3×70A ac(2L-N) | 850VA max single | |||||
1×100A ac(6L-N) | 1200VA max | |||||
3×20A dc(L-N) | 300W max each | |||||
Accuracy | AC:<0.03%Rd + 0.02Rg Typ. / <0.15%Rd + 0.05Rg Guar. | |||||
DC: ±5mA @<1A,±0.5% @ ≥1A | ||||||
Resolution | 1mA | |||||
Distortion | <0.05%Typ. / <0.1% Guar. | |||||
Low-Level Output | ||||||
Quantity | 13 Channels, 16 pin aviation socket | |||||
Voltage outputs range | AC 0-8V, DC 0-10V | |||||
Current outputs range | Nominal 2mA, 10mA max transient | |||||
Output Power | ≥0.5VA | |||||
Accuracy | (0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar. | |||||
(0.8~8 Vrms):<0.02% Typ. / <0.05% Guar. | ||||||
Resolution | 0.25mV | |||||
Distortion(THD%) | <0.05%Typ. / <0.1% Guar. | |||||
Frequency & Phase Angle | ||||||
Frequency Range | DC~1KHZ, 3KHZ transient | |||||
Frequency Accuracy | ±0.5ppm | |||||
Frequency Resolution | 0.001Hz | |||||
Phase Range | 0°~360° | |||||
Phase Accuracy | <0.05°Typ. / <0.1° Guar. 50/60Hz | |||||
Phase Resolution | 0.001° | |||||
IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function) | ||||||
Fiber Ports | 2×100 Base-FX Full Duplex, LC type (Optional to 10/100Mbit, Ethernet RJ45 type) | |||||
Fiber Type | 62.5/125um (Multiple optical fiber, Orange Red) | |||||
Wavelength | 1310nm | |||||
Transmit Distance | >1Km | |||||
Indicator | Spd Green (light): Valid connection
| |||||
Note: Hardware is ready, to be actived. | ||||||
Aux. DC Voltage Source(Battery simulator) | ||||||
Range | 0~350V @ 180W max | |||||
Accuracy | 0.5%Rg Guar. | |||||
Binary Input | ||||||
Quantity | 8 pairs | |||||
Type | wet/dry, measurement | |||||
Threshold | 10~600Vdc or potential free, Programmable | |||||
Time resolution | 100us | |||||
Debounce time | 0~25ms (Software Controlled) | |||||
Time range | Infinite | |||||
Time errors | ±1ms @ 0.001~1s, ±0.1% @>1s | |||||
Galvanic isolation | 4 isolated with each 2 pairs | |||||
Binary Output (Relay Type) | ||||||
Quantity | 4pairs | |||||
Type | Potential free relay contacts,software controlled | |||||
Break Capacity AC | Vmax: 400Vac / Imax:8A / Pmax:2500VA | |||||
Break Capacity DC | Vmax: 300Vdc / Imax:5A / Pmax:150W | |||||
Binary Output (Semiconductor Type) | ||||||
Quantity | 4pairs | |||||
Type | Open-collector, 14 pin Aviation socket | |||||
Break Capacity DC | 5~15Vdc / 5mA, 10mA max
| |||||
Response time | 100us | |||||
Synchronization | ||||||
Synchronization Mode | GPS, SMA type antenna connector / IRIG-B / IEEE1588 | |||||
Power supply & Environment | ||||||
Nominal Input Voltage | 100~240Vac | |||||
Permissible Input Voltage | 85~264Vac, 125~350VDC | |||||
Nominal Frequency | 50/60Hz | |||||
Permissible Frequency | 45Hz~65Hz | |||||
Power Consumption | 1500 VA max | |||||
Connection Type | Standard AC socket 60320 | |||||
Operating Temperature | -10℃~55℃ | |||||
Storage Temperature | -20℃~70℃ | |||||
Humidity | <95%RH, non-condensing | |||||
Others | ||||||
PC Connection | RJ45 Ethernet, 10/100M | |||||
Grounding Terminal | 4mm banana socket | |||||
Weight | 18Kg | |||||
Dimensions(W×D×H) | 468×375×164(mm) |
DC Measurement Input(Transducer calibrator) * Hardware is ready,to be actived. | ||||||
Voltage input | Range | 0~±10V dc | ||||
Max Input | ±11V dc | |||||
Accuracy | <0.02% rg Typ. / <0.05% rg Guar. | |||||
Input Impedance | 1M ohm | |||||
Current Input | Range | 0~±1mA / 1~20mA, auto range | ||||
Max Input | 600mA | |||||
Accuracy | <0.02% rg Typ. / <0.05% rg Guar. | |||||
Input Impedance | 15 ohm | |||||
AC / DC Measurement Input( Standard meter ) * Require extra PCB installed in factory only | ||||||
Input Quantity | 8 channels (blend with binary input pairs) | |||||
Voltage rang | 0~600Vrms (Rg: 0.1V,1V,10V,60V,600V) | |||||
Voltage accuracy | <0.05% Rg | |||||
Current range | Shunt input: 0~5Arms / 0~30Arms (Optional) | |||||
Current accuracy | <0.1% Rg | |||||
Sample rate | 10KHz | |||||
Input impedance | 600KΩ | |||||
Frequency range | 45~65Hz, Accuracy<0.01Hz | |||||
Phase accuracy | 0~360°,<0.2° Typ. | |||||
Energy Meter Calibration * Hardware is ready,to be actived | ||||||
Sensor Usage | Mechanical meters / Electronic meters | |||||
Sensor Output | High level : >4.5V, Low level: <0.2V | |||||
Pulse Input | 1 pulse input port | |||||
Pulse Range | 500KHz pulse input Max. | |||||
Pulse Output | 1 Transistor output, Open-collector, 5-15Vdc/5mA |
Kingsine Electric Automation Co., Ltd.
Who am I ?
Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, and Instrumentation. To date, Kingsine's products have been recognized by customers in more than 80 countries worldwide. We regularly participate in large-scale power and energy exhibitions worldwide, including in the United States, Italy, France, Poland, Australia, Dubai, Turkey, Brazil, Philippines, Malaysia, Indonesia, South Africa, Egypt, and other countries, and have received widespread acclaim.Our protection relay testing equipment is compatible with world-renowned relay protection devices such as ABB, SIEMENS, ALSTOM, MITSUBISHI, Schneider, AREVA, SEL, GE, and others. Kingsine Electric has also established a distribution network with partners in the Americas, Europe, Asia, the Middle East, and other countries to provide comprehensive services.
Kingsine is a core supplier to China's State Grid
The facts demonstrate that China's annual power generation has remained the world's number one, with a projected power generation of 840 billion kilowatt hours in 2022, compared to the United States' projected 430 billion kilowatt hours in the same year. China has built the world's most advanced power transmission system for DC current at 1100KV ultra-high voltage levels and more than 11,000 digitized substations based on the IEC61850 standard. China's power grid has the largest, most advanced, safest and most stable power system in the world. We are honored to be the core supplier for State Grid Corporation of China.
Where did I come from?
Kingsine Electric is located in Shenzhen, the "Innovation Capital of China". We have also established subsidiaries in Canada and Hong Kong. Shenzhen is a benchmark city for the development of China's high-tech industry and is home to leading Chinese companies in various industries. Many of China's top companies, including Huawei, the world's largest communication company; DJI, the world's largest commercial drone company; BYD, the world's largest electric vehicle company (which sold 1.86 million electric vehicles globally in 2022, surpassing Tesla's sales of 1.37 million); and Tencent, one of China's leading internet companies, are based in Shenzhen. Excellent enterprises can influence each other, and as the world's factory, Shenzhen has a highly advanced and comprehensive industrial chain, which provides a reliable guarantee for Kingsine Electric to develop, produce, and manufacture high-tech, high-quality, and reliable products.
Where am I going?
Philosophy
Adhering to the belief of novelty in technology and detail in service, and gradually establishing a global service and sales network with worldwide partners and distributors, Kingsine shall spare no effort to serve customers worldwide with innovative technology, reliable products, and quality online service, making electric testing easier across the world.
Business Principles
Kingsine's business principle is to create value for customers, which is reflected in three aspects.
Firstly, Kingsine uses advanced technology to create powerful product features that offer customers a great operating experience.
Secondly, Kingsine provides high-quality products and services at reasonable prices, ensuring that customers receive high value for their investment.
Thirdly, Kingsine emphasizes reliability and after-sales service, providing quality assurance through lean production and ensuring that products have over 15 years of service life and three years of warranty. Kingsine's after-sales maintenance principle is based on cost accounting, ensuring that after-sales service remains efficient and affordable.Based on our modular product design philosophy, and with the help of efficient video diagnostics, our target for after-sales maintenance service is to complete repairs within 20 days.