Vertical Helix Water Meter For Measuring Bulk Flow Cold Water / Hot Water
The vertical helix water meter has wide measure range, less pressure loss, high accuracy at low flow velocity, minimal initial flow. The optional tele reading with pulse output.
Feature:
Note:
Working condition:
Maximum Permissible Error:
(1) in the lower zone from qmin inclusive up to but excluding qt is ±5%
(2) in the upper zone from qt inclusive up to and including qs is ±2%
(3) Hot water meter ±3%
Data sheet
Model | Dia (mm) | Class ISO4064 | Overload flow (Qs) | Permanent flow (Qp) | Transitional flow (Qt) | Min flow Qmin | Min reading | Max reading |
m3/h | M3 | |||||||
IXLC-50 | 50 | A | 30 | 15 | 4.5 | 1.2 | 0.0002 | 999,999 |
B | 3.0 | 0.45 | ||||||
IXLC-65 | 65 | A | 50 | 25 | 7.5 | 2.0 | 0.0002 | 999,999 |
B | 5.0 | 0.75 | ||||||
IXLC-80 | 80 | A | 80 | 40 | 12 | 3.2 | 0.0002 | 999,999 |
B | 8.0 | 1.2 | ||||||
IXLC-100 | 100 | A | 120 | 60 | 18 | 4.8 | 0.0002 | 999,999 |
B | 12 | 1.8 | ||||||
IXLC-125 | 125 | A | 200 | 100 | 30 | 8 | 0.0002 | 999,999 |
B | 20 | 3 | ||||||
IXLC-150 | 150 | A | 300 | 150 | 45 | 12 | 0.0002 | 999,999 |
B | 30 | 4.5 | ||||||
IXLC-200 | 200 | A | 500 | 250 | 75 | 20 | 0.0002 | 999,999 |
B | 50 | 7.5 | ||||||
IXLC-250 | 250 | A | 800 | 400 | 120 | 32 | 0.0002 | 999,999 |
IXLC-300 | 300 | A | 1200 | 600 | 180 | 48 | 0.0002 | 999,999 |
Dimension (LXLC)
Model | Dia. | L | H | Flange (mm) | ||
(mm) | D1 (OD) | D2 (hole) | Bolt(n-M) | |||
IXLC-50 | 50 | 200 | 253 | 165 | 125 | 4-M16 |
IXLC-65 | 65 | 200 | 268 | 185 | 145 | 4-M16 |
IXLC-80 | 80 | 225 | 284 | 200 | 160 | 8-M16 |
IXLC-100 | 100 | 250 | 295 | 220 | 180 | 8-M16 |
IXLC-125 | 125 | 250 | 310 | 250 | 210 | 8-M16 |
IXLC-150 | 150 | 300 | 339 | 285 | 240 | 8-M20 |
IXLC-200 | 200 | 350 | 382 | 340 | 295 | 8-M20(1.0Mpa) 12-M20(1.6Mpa) |
IXLC-250 | 250 | 400 | 433 | 395 | 350 | 12-M20(1.0Mpa) |
450 | 438 | 405 | 355 | 12-M24(1.6Mpa) | ||
IXLC-300 | 300 | 450 | 483 | 445 | 400 | 12-M20(1.0Mpa) |
500 | 488 | 460 | 410 | 12-M24(1.6Mpa) |
Competitive Advantage:
Shanghai Xunhui Environment Technology Co., Ltd.
Focus on low-carbon energy and environment protection technology, we design and manufacture fluid processing and control products to give our contribution to the sustainable energy develop.
Lots of mega projects have been installed with our products, Shanghai expo center, Shanghai Disney energy center, Beijing Z15 tower, Malaysia GDC energy station, etc. Our technology and practical application experience, allow us to provide our client with products and solutions which meet your expectation on building, improving and mainting equipment. The industries we served:
Our R&D, customer experience and manufacturing center is located in the “Low energy building science center” Hanghzou, China. As a Provincial class Postdoctoral workstation by collaboration with China State Energy research institute, which ensure our advantage from technician, science research & development, equipment. Our main products includes: flowmeters, roots air blower, pump, as well as design consultancy on RO, UF, NF design.